Home > Energy > What are the disadvantages of a 3-phase inverter?

What are the disadvantages of a 3-phase inverter?

Author: Justin

Apr. 29, 2024

5 0

Tags: Energy

3-Phase Inverter - Types, Working and Applications

An inverter is a fundamental electrical device designed primarily for the conversion of direct current into alternating current . This versatile device , also known as a variable frequency drive , plays a vital role in a wide range of applications , including variable frequency drives and high power scenarios such as high voltage direct current (HVDC) power transmission. Its primary function is to control the torque and speed of electrical motors , making a vital role in many industrial and commercial settings. The versatility of inverters extends to their role in HVDC power transmission, where they are crucial in converting the DC power generated in power plants or offshore wind farms into AC power suitable for long transmission .

Contact us to discuss your requirements of customized commercial three phase inverters. Our experienced sales team can help you identify the options that best suit your needs.

In this context , inverters help minimize energy losses and maximize the efficiency of electricity distribution over extensive distances. Here we will discuss about circuit design and working of inverter , types of inverters , advantages , limitations and applications of inverters .

Three Phase Inverter

A three phase inverter is a device that converts dc source into three phase ac output . This conversion is achieved through a power semiconductor switching topology. in this topology , gate signals are applied at 60-degree intervals to the power switches , creating the required 3-phase AC signal. This type of inverter commonly employed in conjunction with photovoltaic(PV) modules or the grid . The fundamental principle behind its operation involves the use of three individual inverter switches , with each switch is dedicated to one of the three output phases. To generate a balanced and synchronized ac output waveform , these switches are precisely controlled. Each switch operates at specific intervals , ensuring that only one switch is active at every 60-degrees of the basic output waveform . In essence , a 3-phase inverter is a crucial component for efficiently converting DC power into 3-phase AC power needed for various applications, especially in renewable energy systems like solar PV installations and industrial setups where three phase power is essential for running machinery and equipment.

Types of Three Phase Inverter

Three phase inverters are classified many types according to their features and characteristics . Some of the inverters are:

  • Voltage Source Inverter

  • Current Source Inverter

  • Cascaded Multilevel Inverter

  • Hybrid Multilevel Inverter

  • Pulse Width Modulated Inverter

Voltage Source Inverter

A voltage source inverter (VSI) is an inverter that converts DC source voltage into an AC output voltage. It is also known as voltage -fed inverter, suitable for situations where the DC source has negligible or low impedance. VSIs are commonly used in Variable-Frequency Drive(VFD) systems to control the speed of 3-phase motors. In this type of inverter DC voltage is very small i.e. negligible and having small impedance .Hence these inverters are also called as voltage fed inverters . These kind of inverters are only used for buck operation and these are used in three phase inverters where the power requirement is high. In VSIs, the DC voltage source is usually provided by battery banks ,consisting of multiple cells connected in series and parallel configurations. This model ensures a reliable and stable DC supply. In some cases, photovoltaic (PV) cells are used as the DC source, harnessing solar energy to power the inverter.

Current Source Inverter

In current source inverter DC current source is converted into AC current at required frequency. In this type of inverters source current is always constant. Hence ,these inverters are called as current fed inverters. These are used only for boost operation and it is not possible to use with more than one motor. The output AC current ‘s frequency is determined by the switching frequencies of various semiconductor devices such as transistors and thyristors. Notably , the defining feature of this inverter is that the input current remains constant. A typical current source inverter setup consists of a DC current source, filters and on an AC load. These inverters are available in both single-phase and three-phase configurations, making them versatile for a wide range of applications. They find use in tasks like starting synchronous motors, power factor correction units, speed control of AC motors, induction heaters, plasma generators, uninterruptible power supplies(UPS),lagging Var compensators and more.

Cascaded Multilevel Inverter

Cascaded Multilevel Inverter is a 3-phase inverter designed for electric utility applications, offering precise control by employing multiple voltage levels to create a stepped waveform. It typically comprises(M-1)/2 H-bridges, each supported by its DC capacitor. These inverters are crucial in renewable energy systems and high-voltage power transmission. By providing enhanced voltage quality and efficient power conversion, they are well- suited for application where stable AC power generation is essential, particularly in the integration of renewable energy sources like solar and wind, as well as in high-voltage transmission systems, ensuring reliable and controlled power delivery over long distances.

Hybrid Multilevel Inverter

The Hybrid Multilevel Inverter is a three-phase inverter specially designed for industrial applications with medium voltage and high power demands. It uniquely combines elements of both current- source and voltage source inverters, offering a versatile solution for complex power requirements. This type of inverter is particularly well-suited for high power applications, including electric vehicle charging stations. Its ability to efficiently handle medium voltage and high-power scenarios makes it a valuable component in modern industries where reliable and controlled power conversion is essential. The hybrid multilevel inverter plays a pivotal role in enhancing power infrastructure, enabling the efficient charging of electric vehicles and meeting the demands of high-power industrial operations.

Pulse Width Modulated Inverter

A Pulse with Modulated (PWM) is a specialized inverter that consists of pulse-width modulation technique to precisely control the output frequency and voltage. This inverter operates by rapidly switching Insulated Gate Bipolar Transistors(IGBTs) on and off, enabling it to generate nearly ideal sinusoidal voltage with minimal harmonic distortion. The key advantage of PWM inverters is their ability to produce high-quality AC power that closely resembles a pure sinusoidal waveform, making them crucial in applications where clean and stable electricity is essential. Includes renewable energy systems such as solar and wind power, Where PWM inverters efficiently convert DC power from solar panels or wind turbines into grid-ready Ac power with minimal distortion. Moreover ,PWM inverters find extensive use in motors drives , providing precise control over the speed and torque of electric motors. Their capability to deliver clean and accurately regulated AC power makes them indispensable in various industrial and commercial applications, ensuring efficient and reliable operation of equipment and machinery.

Working of 3-Phase Inverter

The below circuit is a three phase inverter , designed to convert a direct current(DC) input into a three-phase alternating current(AC) output. In this configuration , three separate single-phase inverter switches are utilized , with each switch being connected to three load terminals simultaneously . To generate a three-phase AC supply , the inverter operates with a 120-degree phase shift between its three arms .This means that each switch in the circuit is turned on and off in a synchronized manner , creating a balanced AC output efficiency , the three-phase inverters are often connected to a single fuse and share the same DC power source .This arrangement simplifies the circuit’s control and protection mechanisms.

In a three-phase inverter , the pole voltage , which represents the voltage applied to the load , is equivalent to the pole voltage in a half-phase inverter used in single-phase applications . However in three-phase inverters , this voltage is distributed across three phases to create a balanced three-phase AC output . There are two primary conduction modes in both single-phase and three-phase inverters i.e.. 120-degree conduction mode and the 180-degree conduction mode. These modes refer to the timing and duration of the switching of the the inverter switches . in 120 degree mode , each switch conducts for 120 degrees of the electrical cycle , while in the 180-degree mode, conduction lasts for 180 degrees. These modes allow for different levels of control and output waveform quality in the inverter operation.

Modes of Conduction in 3-Phase Inverter

There are basically two modes of conduction :

  • 180 degree conduction mode

  • 120 degree conduction mode

180 Degree Conduction Mode

In this conduction mode each device conducts for 180 degrees with activation occurring at 60 degree intervals . The output terminals labeled D, E and F are connected in either star or a three phase delta configuration to the load . this balanced load arrangement is illustrated in the diagram.

During 0 to 60 degree phase angle range , switches S1 , S5 and S6 are in conduction mode . In this period , terminals D and F are connected to the positive point of the power source , while terminal E is linked to the source’s negative point . Additionally , there is an R/2 resistance between the two ends of the neutral and the positive terminals , while on R resistance is present between the neutral and the negative terminal.

This configuration ensures that the three phase inverter operates with a specific switching pattern , producing a balanced output across its terminals while controlling the flow of current through the load . Such precise control is essential for various applications , including motor drives and power systems , where maintaining balanced and controlled three phase ac power is crucial.

Load voltages are given as ,

VDN= V/3

VEN= -2V/3

VFN= V/3

Line voltages are ,

VDE = VDN – VEN = v

VEF = VEN – VFN= -v

VFD= VFN- VDN = 0

120 Degree Conduction Mode

In this conduction mode , each electronic device operates for 120 degrees , making it suitable for a delta connected load . This mode generates a six step waveform across one of its phases , where only specific devices conduct at any given instant , precisely at 120 degree intervals. In the load connection , the ‘D’ terminal connects to the positive end of the source , while the ‘E’ terminal links to the source negative terminal . The ‘F’ terminal remains in a floating state , meaning it is not connected to either the positive or negative side of the source .The phase voltages across the load correspond to the voltages , providing a controlled and balanced output across the phases.

phase voltages are equal to line voltages.

VDE = V

VEF = -V/2

VFD = – V

From the above waveform :

  • From 0-60 :

    s1 and s6 are in conduction while remaining switches are opened.

  • From 60 – 120 :

    s1 and s2 are in conduction while remaining switches are opened.

  • From 120 – 180 :

    s3 and s2 are in conduction while remaining switches are opened .

  • From 180 – 240 :

    s3 and s4 are in conduction while remaining switches are opened.

  • From 240 – 300 :

    s5 and s4 are in conduction while remaining switches are opened.

  • From 300 – 360 :

    s5 and s6 are in conduction while remaining switches are opened.

Advantages of 3-Phase Inverter

  • A three phase inverter transmits more power over long distances compared to single phase power.

  • Three phase inverter has high efficiency due to the balanced load distribution across all the three phases . So, that it leads to reduced energy loss and power operating costs.

  • Three phase inverters provide more stable and balanced output voltage and current which leads to better power quality.

  • Three phase inverters can help in minimizing harmonic distortion in electrical systems which reduces power quality.

  • Three phase inverters are less affected by overvoltage events .

  • Three phase inverters are more compatible with electrical grid.

  • Three phase inverters can be smaller and lighter than the single phase inverters.

Disadvantages of 3-Phase Inverter

  • These are more expensive due to complex design , additional complexity and higher power capacity .

  • These are more complex to install due to and require careful attention to phase balancing and load distribution which requires experienced users .

  • These are larger and heavier that make installation and maintenance more difficult .

  • These inverters can sometimes produces electromagnetic interference which may effects electronic devices and systems .

  • These are used in high power applications and may not be efficient when operating low power levels which leads lo energy wastage in smaller installations.

Applications of 3-Phase Inverter

  • Three phase inverters are used in variable frequency drive applications .

  • These are used in high power applications like HVDC power transmission.

  • These are used in agriculture for irrigation pumps and other farming practices.

  • These are used to power heavy machinery such as crushers , conveyors etc.

  • These are used in electric vehicles i.e. for converting DC power from vehicle’s battery into three phase AC power to drive the electric motor .

  • These are used to control and power electric motors and are found in pumps , fans , conveyors , manufacturing equipment etc.

    If you are looking for more details, kindly visit connecting single phase inverter to three phase.

Solved Example of 3-Phase Inverter

1. A single phase half bridge inverter has a resistance of 5 ohms and input DC voltage as 100V . Calculate

  • the rms voltage occurring at the fundamental frequency
  • output power
  • peak current
  • average current
  • Harmonic rms voltage
  • total harmonic distortion

Solution : Given R = 5 ohms , E = 100V

  • The rms voltage occurring at the fundamental frequency E1RMS = 0.9 * 100 = 90v

  • RMS output voltage = E0RMS = E = 100v

  • output power = E^2 /R = (100)^2 / 5 = 2000W

  • Peak current Ip = E0/R = 100/5 = 20A

  • Average current = Ip/2 = 20/2 = 10A

  • Harmonic RMS voltage En = { (E0RMS)^2 – (E1RMS)^2 }^0.5 = [(100)^2 – (90)^2]^0.5 = 43.588v

  • Total harmonic distortion = En/E1RMS = 43.588/90 = 0.4843 * 100% = 48.43%

Conclusion

Thus this is an overview of three phase inverter- types , working , advantages , limitations , applications. Three-phase inverters find extensive use in variable-frequency drives (VFDs) , which are essential for controlling the speed and torque of electric motors in industrial and commercial settings . Additionally , these inverters are prominently featured in high-power applications such as high voltage direct current (HVDC) power transmission , where they play a crucial role in converting DC power from source like power plants or renewable energy systems into AC power suitable for long-distance transmission . The three-phase inverter is a versatile and indispensable component in the realm of power electronics . It facilitates the conversion of DC voltage into 3-pase AC power , with applications spanning variable-frequency drives and high-power scenarios , notably in HVDC power transmission , contributing significantly to the efficiency and control of various electrical systems.

FAQs on 3-Phase Inverter

Are three-phase inverters more complex to install than single phase inverters ?

Three-phase inverters may require additional wiring and configuration compared to single phase inverters due to the three- phase power distribution.

Can three-phase inverters be used in off-grid configuration ?

Yes , three-phase inverters can be used in off-grid applications , but they are often used in grid-tied systems . Specialized off-grid inverters are also available .

Do three-phase inverters produce harmonics in the output waveform ?

While , three-phase inverters can produce cleaner output waveforms , they may still introduce some harmonics . To minimize harmonics , appropriate filtering or PWM control technique can be employed .



Like Article

Suggest improvement

Share your thoughts in the comments

Please to comment...

Single Phase Inverters vs. 3 Phase Inverters: What's the ...

Inverters are an essential component of many electrical systems, converting DC power to AC power for a wide range of applications. Two types of inverters commonly used in these applications are single phase inverters and 3 phase inverters. While they both serve the same purpose, there are key differences between the two types of hybrid inverters that make each more suitable for certain applications. In this article, we'll explore the differences between these two types of inverters, including their advantages, disadvantages, and typical applications.



Single Phase Inverters


Single phase inverters are the most common type of inverter used in residential and small commercial applications. They operate by generating AC power using a single sine wave, which causes the voltage to oscillate between positive and negative 120 or 240 times per second. This sine wave alternates between positive and negative values, creating a waveform that resembles a simple sine curve.


One of the main advantages of single phase inverters is their relatively low cost and simple design. Because they use a single sine wave, they require less complex electronics and are typically less expensive to manufacture. However, this simplicity also comes with some disadvantages. Single phase inverters have a lower power output and less stable voltage regulation than 3 phase inverters, making them less suitable for large-scale or high-power applications.


Typical applications of single phase inverters include residential solar power systems, small appliances, and other low-power applications. They are also commonly used in areas where the power grid is unstable or unreliable, as they can be easily connected to battery backup systems. Click to View BSLBATT Single Phase Inverter.


3 Phase Inverters


3 phase inverters, as the name suggests, use three sine waves (three sine waves with a phase difference of 120 degrees from each other) to generate AC power, resulting in a voltage that oscillates between positive and negative 208, 240, or 480 times per second. This allows for greater power output, more stable voltage regulation, and greater efficiency compared to single phase inverters. However, they are also more complex and expensive to manufacture.


One of the key advantages of 3 phase inverters is their ability to provide a high level of power output. They are commonly used in large-scale commercial and industrial power systems, electric vehicles, and other high-power applications. Their greater efficiency and stable voltage regulation also make them suitable for applications where reliable power is critical.


However, 3 phase inverters also have some disadvantages. They are typically more expensive than single phase inverters and require more complex electronics to operate. This complexity can make them more difficult to install and maintain. Click to View BSLBATT 3 Phase Inverter.


Comparison of Single Phase and 3 Phase Inverters


When choosing between single phase and 3 phase inverters, several factors must be considered. The voltage and current output of each type of inverter are different, with single phase inverters providing 120 or 240 volts AC and 3 phase inverters providing 208, 240, or 480 volts AC. The power output and efficiency of the two types of inverters are also different, with 3 phase inverters typically providing higher power output and greater efficiency due to their use of three sine waves.


Other factors to consider when choosing between single phase and 3 phase inverters include the size and complexity of the application, the need for voltage regulation, and the cost and efficiency of the inverter. For smaller applications, such as residential solar power systems and small appliances, single phase inverters may be more suitable due to their lower cost and simpler design. For larger applications, such as commercial and industrial power systems, 3 phase inverters are often the better choice due to their higher power output and greater efficiency.



Three-Phase Inverter

Single-Phase Inverter

Definition

Generates AC power using three sine waves that are 120 degrees out of phase with each other

Generates AC power using a single sine wave

Power Output

Higher power output

Lower power output

Voltage Regulation

More stable voltage regulation

Less stable voltage regulation

Design Complexity

More complex design

Simpler design

Cost

More expensive

Less expensive

Advantages

Suitable for large-scale commercial and industrial power systems and electric vehicles; More stable voltage regulation; Higher power output

Less expensive; Simpler in design

Disadvantages

More complex in design; More expensive

Lower power output; Less stable voltage regulation


Single Phase to 3 Phase Inverter


However, there may be instances where single phase power is available, but a 3 phase inverter is needed for the application. In these cases, it is possible to convert single phase power to three phase power using a device called a phase converter. A phase converter takes the single phase input and uses it to generate two additional phases of power, which are combined with the original phase to produce a three-phase output. This can be achieved using various types of phase converters, such as static phase converters, rotary phase converters, and digital phase converters.


Conclusion


In conclusion, the choice between single phase and 3 phase inverters depends on the specific requirements of the application. Single phase inverters are simpler and less expensive but have lower power output and less stable voltage regulation, while 3 phase inverters are more complex and expensive but offer greater power output, efficiency, and stability. By considering the factors discussed in this article, you can choose the right type of inverter for your specific needs. Or if you haven't you don't have any idea about choosing the right hybrid solar inverter, then you can contact our product manager for the most cost effective inverter quote!

Want more information on inverter for 5kw solar system? Feel free to contact us.


Comments

0